Aerogel Blanket vs Conventional Insulation

For the same steam line, replacing "150 mm aluminum silicate + color steel plate" with "multi-layer 10 mm aerogel + glass cloth + 50 mm aluminum silicate" cut total thickness from 150 mm to 80 mm, reduced surface heat loss from 439 W/m² to 138 W/m² and delivered a 74.6% energy saving rate.

Item Conventional scheme Aerogel scheme
Total insulation thickness 150 mm 80 mm
Pipe surface temperature 40 ℃ 18 ℃
Surface heat loss 439 W/m² 138 W/m²
Heat loss along the pipe 578 W/m 147 W/m
Energy saving rate — 74.6%
Temperature drop per 1 km 40 ℃ 10 ℃

Basis: ambient 9 ℃, wind 3 m/s, steam 370 ℃ / 3 MPa, flow 20 t/h (per GB/T 8175-2008).

Steam piping · District heating · Tanks

Gallery

Work with us

Need help specifying?

Tell us your operating temperature, medium and installation space — we will recommend the build-up and thickness.