Preheating Tank, Conch Group Baima Cement Plant

A demonstration area of about 2 m² was brush-applied: first KNF-240 at 1–1.5 mm, then KNF-150 at 1–1.5 mm. Heat loss per unit area measured 1709 W/m² uncoated; after applying 2–3 mm of nano coating, heat loss fell by an average of 80–90%.

1709 W/m²
Heat loss, uncoated
80–90%
Heat loss reduction
About 2 m²
Demonstration area
KNF-240 + KNF-150
Coating build-up
Project overview

Project notes

A demonstration area of about 2 m² was brush-applied: first KNF-240 at 1–1.5 mm, then KNF-150 at 1–1.5 mm. Heat loss per unit area measured 1709 W/m² uncoated; after applying 2–3 mm of nano coating, heat loss fell by an average of 80–90%.

Project type Industrial equipment energy saving
Timeline Construction & test data

Key figures

  • Heat loss, uncoated — 1709 W/m²
  • Heat loss reduction — 80–90%
  • Demonstration area — About 2 m²
  • Coating build-up — KNF-240 + KNF-150

Gallery

Work with us

Need help specifying?

Tell us your operating temperature, medium and installation space — we will recommend the build-up and thickness.